Residential air exchange rates in three major US metropolitan areas: Results from the Relationship Among Indoor, Outdoor, and Personal Air Study 1999–2001

Yamamoto, N; Shendell, D; Winer, A; Zhang, J

HERO ID

1060834

Reference Type

Journal Article

Year

2010

Language

English

PMID

19874401

HERO ID 1060834
In Press No
Year 2010
Title Residential air exchange rates in three major US metropolitan areas: Results from the Relationship Among Indoor, Outdoor, and Personal Air Study 1999–2001
Authors Yamamoto, N; Shendell, D; Winer, A; Zhang, J
Journal Indoor Air
Volume 20
Issue 1
Page Numbers 85-90
Abstract We report approximately 500 indoor-outdoor air exchange rate (AER) calculations based on measurements conducted in residences in three US metropolitan areas in 1999-2001: Elizabeth, New Jersey; Houston, Texas; and Los Angeles County, California. Overall, a median AER across these urban areas and seasons was 0.71 air changes per hour (ACH, or per hour; n = 509) while median AERs measured in California (n = 182), New Jersey (n = 163), and Texas (n = 164) were 0.87, 0.88, and 0.47 ACH, respectively. In Texas, the measured AERs were lower in the summer cooling season (median = 0.37 ACH) than in the winter heating season (median = 0.63 ACH), likely because of the reported use of room air conditioners as Houston is typically hot and humid during the summer. The measured AERs in California were higher in summer (median = 1.13 ACH) than in winter (median = 0.61 ACH). Because the summer cooling season in Los Angeles County is less humid than in New Jersey or Texas, natural ventilation through open windows and screened doors likely increased measured AER in California study homes. In New Jersey, AER were similar across heating and cooling seasons, although the median AER was relatively lower during the spring. PRACTICAL IMPLICATIONS: Adequate ventilation or air exchange rate (AER) for an indoor environment is important for human health and comfort, and relevant to building design and energy conservation and efficiency considerations. However, residential AER data, especially measured by more accurate non-toxic tracer gas methodologies, are at present quite limited worldwide, and are insufficient to represent the variations across regions and seasons within and between homes, including apartments and condominiums in more densely populated urban areas. The present paper presents quantitative and qualitative data to characterize residential AERs in three US urban areas with different climate attributes.
Doi 10.1111/j.1600-0668.2009.00622.x
Pmid 19874401
Wosid WOS:000273459200009
Is Certified Translation No
Dupe Override No
Is Public Yes
Language Text English
Keyword Air exchange rate; Perfluoro-methyl-cyclohexane; Air changes per hour; Ventilation rates; Perfluorocarbon tracer gas; Urban residences