Target loads of atmospheric sulfur deposition for the protection and recovery of acid-sensitive streams in the Southern Blue Ridge Province

Sullivan, TJ; Cosby, BJ; Jackson, WA

HERO ID

1785443

Reference Type

Journal Article

Year

2011

Language

English

PMID

21816535

HERO ID 1785443
In Press No
Year 2011
Title Target loads of atmospheric sulfur deposition for the protection and recovery of acid-sensitive streams in the Southern Blue Ridge Province
Authors Sullivan, TJ; Cosby, BJ; Jackson, WA
Journal Journal of Environmental Management
Volume 92
Issue 11
Page Numbers 2953-2960
Abstract An important tool in the evaluation of acidification damage to aquatic and terrestrial ecosystems is the critical load (CL), which represents the steady-state level of acidic deposition below which ecological damage would not be expected to occur, according to current scientific understanding. A deposition load intended to be protective of a specified resource condition at a particular point in time is generally called a target load (TL). The CL or TL for protection of aquatic biota is generally based on maintaining surface water acid neutralizing capacity (ANC) at an acceptable level. This study included calibration and application of the watershed model MAGIC (Model of Acidification of Groundwater in Catchments) to estimate the target sulfur (S) deposition load for the protection of aquatic resources at several future points in time in 66 generally acid-sensitive watersheds in the southern Blue Ridge province of North Carolina and two adjoining states. Potential future change in nitrogen leaching is not considered. Estimated TLs for S deposition ranged from zero (ecological objective not attainable by the specified point in time) to values many times greater than current S deposition depending on the selected site, ANC endpoint, and evaluation year. For some sites, one or more of the selected target ANC critical levels (0, 20, 50, 100 mu eq/L) could not be achieved by the year 2100 even if S deposition was reduced to zero and maintained at that level throughout the simulation. Many of these highly sensitive streams were simulated by the model to have had preindustrial ANC below some of these target values. For other sites, the watershed soils contained sufficiently large buffering capacity that even very high sustained levels of atmospheric S deposition would not reduce stream ANC below common damage thresholds. (C) 2011 Elsevier Ltd. All rights reserved.
Doi 10.1016/j.jenvman.2011.07.014
Pmid 21816535
Wosid WOS:000295299600013
Url /www.sciencedirect.com/science/article/pii/S0301479711002799
Is Certified Translation No
Dupe Override No
Is Public Yes
Language Text English
Keyword Sulfur; Critical load; Target load; Acidification; Stream; Modeling