A new method for using O18 to trace ozone deposition

Subke, JA; Toet, S; D'Haese, D; Crossman, Z; Emberson, LD; Barnes, JD; Ashmore, MR; Evershed, RP; Ineson, P

HERO ID

199776

Reference Type

Journal Article

Year

2009

Language

English

PMID

19241413

HERO ID 199776
In Press No
Year 2009
Title A new method for using O18 to trace ozone deposition
Authors Subke, JA; Toet, S; D'Haese, D; Crossman, Z; Emberson, LD; Barnes, JD; Ashmore, MR; Evershed, RP; Ineson, P
Journal Rapid Communications in Mass Spectrometry
Volume 23
Issue 7
Page Numbers 980-984
Abstract Isotopically labelled ozone (18O3) is an ideal tool to study the deposition of O3 to plants and soil, but no studies have made use of it due to the technical difficulties in producing isotopically enriched ozone. For 18O3 to be used in fumigation experiments, it has to be purified and stored safely prior to fumigations, to ensure that the label is present predominantly in the form of O3, and to make efficient use of isotopically highly enriched oxygen. We present a simple apparatus that allows for the safe generation, purification, storage, and release of 18O3. Following the purification and release of O3, about half (by volume) of the 18O is present in the form of O3. This means that for a given release of 18O3 into the fumigation system, a roughly identical volume of 18O2 is released. However, the small volume of this concurrent 18O2 release (100 nmol mol-1 in our experiment) results in only a minor shift of the much larger atmospheric oxygen pool, with no detectable consequence for the isotopic enrichment of either soil or plant materials. We demonstrate here the feasibility of using 18O as an isotopic tracer in O3 fumigations by exposing dry soil to 100 nmol mol-1 18O3 for periods ranging from 1 to 11 h. The 18O tracer accumulation in soil samples is measured using gas chromatography/isotope ratio mass spectrometry (GC/IRMS), and the results show a linear increase in 18O/16O isotope ratio over time, with significant differences detectable after 1 h of exposure. The apparatus is adapted for use with fumigation chambers sustaining flow rates of 1 m3 min-1 for up to 12 h, but simple modifications now allow larger quantities of O3 to be stored and continuously released (e.g. for use with open-top chambers or FACE facilities). Copyright © 2009 John Wiley & Sons, Ltd.
Doi 10.1002/rcm.3961
Pmid 19241413
Wosid WOS:000264644300006
Is Certified Translation No
Dupe Override No
Is Public Yes
Language Text English
Is Qa No
Relationship(s)