Sorption of per- and polyfluoroalkyl substances (PFASs) on filter media: implications for phase partitioning studies

Chandramouli, B; Benskin, JP; Hamilton, MC; Cosgrove, JR

HERO ID

3981248

Reference Type

Journal Article

Year

2015

Language

English

PMID

25220773

HERO ID 3981248
In Press No
Year 2015
Title Sorption of per- and polyfluoroalkyl substances (PFASs) on filter media: implications for phase partitioning studies
Authors Chandramouli, B; Benskin, JP; Hamilton, MC; Cosgrove, JR
Journal Environmental Toxicology and Chemistry
Volume 34
Issue 1
Page Numbers 30-36
Abstract Per- and polyfluoroalkyl substances (PFASs), including perfluorooctanoic acid (PFOA) and perfluorooctanesulfonic acid (PFOS), are ubiquitous in the environment. Investigations into their fate and potential phase-partitioning behavior require separating solid from aqueous phases via filtration. However, sorption of aqueous-phase PFASs on filtration media may lead to underestimation of PFAS concentrations in the aqueous phase. The authors investigated the sorption of perfluoroalkyl carboxylates, perfluoroalkyl sulfonates, perfluoroalkyl phosphonic acids, perfluoroalkyl phosphinic acids (PFPiAs), polyfluoroalkyl phosphate monoesters, polyfluoroalkyl phosphate diesters (diPAPs), fluorotelomer sulfonates, and perfluorooctane sulfonamide on filtration media. The effects of concentration (3 spiking levels), filter media (4 types), matrix (4 matrices), and compound structure on sorption are reported. Glass fiber filtration resulted in the least sorption, whereas polytetrafluoroethylene filters resulted in the most sorption (up to 98%). Analyte concentration had no significant effect. Sorption was generally consistent across matrix types except for samples affected by aqueous film forming foam deployment, which displayed high sorption of PFOS on nylon filters. Sorption usually increased with an increasing number of carbon or fluorine atoms and was most pronounced for PFPiAs and diPAPs (30–75% sorption). Overall, glass fiber filters are more recommended than nylon filters in environmental samples when phase separation is required. Use of filtration media for PFAS must be preceded by matrix-specific testing to account for unpredictable effects.
Doi 10.1002/etc.2751
Pmid 25220773
Wosid WOS:000346789800005
Is Certified Translation No
Dupe Override No
Is Public Yes
Language Text English
Keyword Fluorochemicals; Analytical chemistry; Analytical bias; Filter sorption; Environmental partitioning