MIRD Pamphlet No. 14 revised: A dynamic urinary bladder model for radiation dose calculations. Task Group of the MIRD Committee, Society of Nuclear Medicine

Thomas, SR; Stabin, MG; Chen, CT; Samaratunga, RC

HERO ID

4850117

Reference Type

Journal Article

Year

1999

Language

English

PMID

10210232

HERO ID 4850117
In Press No
Year 1999
Title MIRD Pamphlet No. 14 revised: A dynamic urinary bladder model for radiation dose calculations. Task Group of the MIRD Committee, Society of Nuclear Medicine
Authors Thomas, SR; Stabin, MG; Chen, CT; Samaratunga, RC
Journal Journal of Nuclear Medicine
Volume 40
Issue 4
Page Numbers 102S-123S
Abstract <strong>UNLABELLED: </strong>The constant-volume urinary bladder model in the standard MIRD Pamphlet No. 5 (Revised) phantom has recognized limitations. Various investigators have developed detailed models incorporating more physiologically realistic features, such as expanding bladder contents and residual volume, and variable urinary input rate, initial volume and first void time. We have reviewed these published models and have developed a new model for calculation of radiation absorbed dose to the urinary bladder wall incorporating these aspects.<br /><br /><strong>METHODS: </strong>The model consists of a spherical source with variable volume to simulate the bladder contents and a wall represented by a spherical shell of constant volume. The wall thickness varies as the source expands or contracts. The model provides for variable urine entry rate (three different hydration states), initial bladder contents volume, residual volume and first void time. The voiding schedule includes an extended nighttime gap during which the urine entry rate is reduced to one-half the daytime rate.<br /><br /><strong>RESULTS: </strong>Radiation-absorbed dose estimates have been calculated for the bladder wall surface (including photon and electron components) and at several depths in the wall (electron component) for 2-18F-fluoro-2-deoxy-D-glucose, 99mTc-diethylenetriaminepentaacetic acid (DTPA), 99mTc-HEDP, 99mTc-pertechnetate, 99mTc-red blood cells (RBCs), 99mTc-glucoheptonate, 99mTc-mercaptoacetyltriglicine chelator (MAG3), 99mTc-methylene diphosphonate (MDP), 99mTc-hexamethylpropylene amine oxime (HMPAO), 99mTc-human serum albumin (HSA), 99mTc-MIBI (rest and stress), 123I-/124I-/131I-OIH, 123I/131I-NaI, 125I-iothalamate, 111In-DTPA and 89Sr-SrCl.<br /><br /><strong>CONCLUSION: </strong>The new model tends to give a higher radiation absorbed dose to the bladder wall surface than the previous models. Large initial bladder volumes and higher rates of urine flow into the bladder result in lower bladder wall dose. The optimal first voiding time is from 40 min to 3 hr postadministration, depending on radiopharmaceutical. The data as presented in tabular and graphic form for each compound provide guidance for establishing radiation absorbed dose reduction protocols.
Pmid 10210232
Is Certified Translation No
Dupe Override No
Is Public Yes
Language Text English