[Simultaneous determination of phthalates and parabens in cosmetic products by gas chromatography/mass spectrometry coupled with solid phase extraction]

Shen, H; Ying, L; Cao, Y; Pan, G; Zhou, L

HERO ID

675420

Reference Type

Journal Article

Year

2007

Language

Chinese

PMID

17580703

HERO ID 675420
In Press No
Year 2007
Title [Simultaneous determination of phthalates and parabens in cosmetic products by gas chromatography/mass spectrometry coupled with solid phase extraction]
Authors Shen, H; Ying, L; Cao, Y; Pan, G; Zhou, L
Journal Sepu / Chinese Journal of Chromatography
Volume 25
Issue 2
Page Numbers 272-275
Abstract Studies have been carried out on the simultaneous determination of 8 phthalates, i. e. di-ethyl phthalate (DEP) , di-propyl phthalate (DPP) , di-isobutyl phthalate (DIBP) , dibutyl phthalate (DBP) , benzyl butyl phthalate ( BBP) , di-cyclohexyl phthalate (DCHP) , di-(2-ethylhexyl) phthalate (DEHP), di-octyl phthalate (DOP) and 4 parabens, i. e. methylparaben (MPB), ethylparaben (EPB), propyl paraben (PPB), and butyl paraben (BPB) by gas chromatography in combination with mass spectrometry (GC/MS) in electron ionisation mode (EI) with selected-ion monitoring (SIM) acquisition method. The phthalates and parabens in 15 cosmetic products, including hair sprays, perfumes, deodorants, cream, lotion, etc. were determined. The determination of the samples were performed after sonication-assisted extraction with methanol, cleaned up with an LC-C18 column (3 mL) and analyzed by GC/MS method. The base peak (m/z 149) of the phthalates and the base peak (m/z 121) of the parabens were selected for the screening studies. The characteristic ions, m/z 121, 149, 177, 222 for DEP; m/z 149, 191, 209 for DPP; m/z 57, 149, 223 for DIBP; m/z 104, 149 for DBP; m/z 91, 132, 149, 206 for BBP; m/z 55, 149, 167 for DCHP; m/z 113, 149, 167, 279 for DEHP; m/z 149, 279 for DOP; m/z 65, 93, 121, 152 for MPB; m/z 93, 121, 138, 166 for EPB; m/z 93, 121, 138, 180 for PPB; and m/z 93, 121, 138, 194 for BPB were chosen for quantitative studies. These techniques are capable to detect phthalates and parabens at the level of 0. 1 -5. 0 microg/kg. Overall recoveries were 80% - 100% with relative standard deviations (RSDs) less than 10%. Only one of the 15 examined samples was free from phthalates and parabens. The rest 14 samples were found to contain at least 3 or more of these phthalates and/or parabens. The predominant phthalates detected in the studied samples were MPB, PPB, DPP, DCHP and DEHP. The residue levels were at 1. 42 -4 278 mg/kg.
Pmid 17580703
Url https://www.scopus.com/inward/record.uri?eid=2-s2.0-57149122053&partnerID=40&md5=9d6ca6a46944b4155e9cd8d7023ad764
Is Certified Translation No
Dupe Override No
Comments Scopus URL: https://www.scopus.com/inward/record.uri?eid=2-s2.0-57149122053&partnerID=40&md5=9d6ca6a46944b4155e9cd8d7023ad764
Is Public Yes
Language Text Chinese
Keyword Cosmetics/ analysis; Gas Chromatography-Mass Spectrometry/ methods; Parabens/ analysis; Phthalic Acids/ analysis; Reproducibility of Results; Solid Phase Extraction/ methods
Is Qa No